An add-on chamber heater is a separate box that sits in your enclosure, heats the air and filters it. The one HelixScreen understands in detail is the BIGTREETECH Panda Breath.
HelixScreen does not install or configure it. The heater is a network device that talks to Klipper, so Klipper has to be told about it first — and that part is the same whether or not you use HelixScreen. Once Klipper knows about it, HelixScreen finds it on its own with nothing for you to set: the chamber temperature appears in the Temperatures widget, presets can set a chamber target, and a diagnostics card shows the heater’s health.
This page covers getting Klipper to that point. What you see afterwards is in Temperature.
Step 1 — Put the heater on your network
Section titled “Step 1 — Put the heater on your network”Power the unit up and join it to your Wi-Fi following BIGTREETECH’s instructions
(the unit publishes its own setup access point on first boot). Then find the
address your Klipper host can reach it at — either its IP address from your
router, or the name it advertises, usually PandaBreath.local.
Check from the machine Klipper runs on:
ping PandaBreath.localIf the name does not resolve, use the IP address everywhere below instead. Give the unit a DHCP reservation in your router if you can — the address ends up in your Klipper config, and a heater that moves address goes offline.
Step 2 — Choose which firmware it runs
Section titled “Step 2 — Choose which firmware it runs”Two firmwares work with HelixScreen. You do not have to change anything to use the one it came with.
| Stock (as shipped) | DragonBreath (third-party) | |
|---|---|---|
| Flashing needed | No | Yes, over Wi-Fi |
| Chamber heating and filtration | Yes | Yes |
| Filament drying | Yes, from HelixScreen or the unit | From the unit only |
| Fault reporting in HelixScreen | No | Yes, with a Reset button |
| Filter-fan speed and control in HelixScreen | No | Yes |
| Heating-element temperature in HelixScreen | No | Yes |
| Offline warning in HelixScreen | Yes | Yes |
Stock is fine, and it is the right choice if you would rather not flash anything. DragonBreath reports more, so HelixScreen can show more. Everything in the rest of this page applies to both unless a step says otherwise.
Snapmaker U1 owners: skip to the U1 shortcut — your printer has a menu for this and you do not need to edit any files.
Step 3 — Tell Klipper about the heater
Section titled “Step 3 — Tell Klipper about the heater”Klipper needs two things: a small add-on module, and a few lines in your config. Both projects below ship an installer that does it for you.
You need SSH access to the machine running Klipper.
If you are on stock firmware
Section titled “If you are on stock firmware”cd ~git clone https://github.com/justinh-rahb/pandabreath-klippercd pandabreath-klipper./install.sh --host PandaBreath.localsudo systemctl restart klipperUse --dry-run first if you want to see what it will change. If your Klipper
install is in a non-standard place, the installer takes --klipper-dir,
--config-dir and --printer-cfg to point it at the right paths.
To write the config by hand instead, copy panda_breath.py into Klipper’s
klippy/extras/ folder and add this to printer.cfg:
[panda_breath]firmware: stockhost: PandaBreath.localport: 80
[heater_generic panda_breath]heater_pin: panda_breath:pwmsensor_type: panda_breathcontrol: watermarkmax_delta: 0.5min_temp: 15max_temp: 80
[verify_heater panda_breath]check_gain_time: 360hysteresis: 5heating_gain: 1Aim to have the unit on BIGTREETECH firmware 1.0.3 or newer — earlier versions are missing sensor fault detection.
If you are on DragonBreath firmware
Section titled “If you are on DragonBreath firmware”Flash it first: open the unit’s own web page in a browser, use its Firmware
Update feature to upload the dragonbreath-<version>.bin file from the
project’s releases, and let
it reboot. It carries your Wi-Fi settings across, so it should rejoin by itself.
The stock firmware stays on the unit and you can switch back to it later.
Then install the Klipper side:
cd ~git clone https://github.com/plastikman/dragonbreath-klippercd dragonbreath-klipper./install.shsudo systemctl restart klipperSet the address in the [dragonbreath] section of your config:
[dragonbreath]host: dragonbreath.local # or the unit's IP address
[heater_generic dragonbreath]heater_pin: dragonbreath:pwmsensor_type: dragonbreathcontrol: watermarkmax_delta: 2.0min_temp: 0max_temp: 75
[verify_heater dragonbreath]check_gain_time: 300hysteresis: 5heating_gain: 1
[output_pin dragonbreath_filter]pin: dragonbreath:filterThe [output_pin] section is what gives you the filter-fan toggle in HelixScreen.
To have Moonraker keep the module updated, add this to moonraker.conf:
[update_manager dragonbreath-klipper]type: git_repopath: ~/dragonbreath-klipperorigin: https://github.com/plastikman/dragonbreath-klipper.gitprimary_branch: mainmanaged_services: klipperThe two section names must match.
[panda_breath]goes with[heater_generic panda_breath];[dragonbreath]goes with[heater_generic dragonbreath]. If they differ, Klipper will not start.
Snapmaker U1 with extended firmware
Section titled “Snapmaker U1 with extended firmware”Nothing to install and no files to edit — it is already on the printer.
- Open
http://<your-printer-ip>:9091in a browser. - Find Panda Breath Chamber Heater under Snapmaker Components.
- Set it to Auto (recommended) or Manual, and enter the heater’s address when asked.
Auto lets the unit hold the chamber itself once the bed is hot, which is gentler on long prints; HelixScreen shows Mode: External while it is doing that. Manual keeps every decision with Klipper. Either works with HelixScreen.
Setting it back to Disabled removes the configuration cleanly.
Step 4 — Restart and check
Section titled “Step 4 — Restart and check”Restart Klipper (FIRMWARE_RESTART from any console, or the menu in
Fluidd/Mainsail). If Klipper refuses to start, the error names the section it did
not like — usually a typo in a section name, or the two names not matching.
In HelixScreen you should now see:
- A chamber row in the Temperatures widget on the home panel
- A chamber target you can set from the temperature panel and from presets that call for one, such as ABS
- A diagnostics card under the graph when you open the chamber temperature view — see Temperature for what each part of it means
- On stock firmware, a Start Drying button on that card — see Drying Filament in the Chamber
Nothing needs to be enabled in HelixScreen for any of that.
If HelixScreen picks the wrong heater
Section titled “If HelixScreen picks the wrong heater”HelixScreen picks the chamber heater by name, and gets it right for anything
called chamber, enclosure, cavity, or named after the appliance. If your
setup has more than one generic heater and it chooses badly, set it yourself:
Settings > Devices > Sensors > Temperature Sensors, then use the Chamber Heater dropdown. Leaving it on Auto keeps the automatic pick; None disables the chamber entirely.
Note that choosing a different heater there also turns off the diagnostics card, because the diagnostics belong to the appliance rather than to whatever heater you picked.
Troubleshooting
Section titled “Troubleshooting”“Heater offline” in the diagnostics card. The unit has stopped answering on the network while Klipper carries on reporting its last temperature. Check it has power and is still on Wi-Fi. Brief dropouts are normal and are ignored; the warning only appears once the unit has been unreachable for a while. A heater that goes offline often usually has a weak signal where it sits, or an address that changed — a DHCP reservation fixes the second.
The chamber never reaches its target. These heaters are slow, and the chamber warms far more slowly than the heating element inside the unit. A target only a few degrees above room temperature can also sit unreached for a long time. Check your enclosure is actually closed.
The target will not go above a certain point. Both firmwares cap what they
accept — DragonBreath refuses targets above 70 °C — and HelixScreen will not offer
more than the limit in your config’s max_temp.
“Mode: External” is showing and I did not do that. Something other than HelixScreen is driving the heater: the unit’s own web page, a button on the unit, or its built-in Auto mode. It is informational, not a fault.
The filter fan says “Device” and the toggle will not respond. The unit is running the fan itself — during warm-up, or purging after a heating cycle — and your request cannot override it. It returns to normal when the unit is done.
A note on security
Section titled “A note on security”The stock firmware’s network interface has no password. Anyone on your network can reach the heater and turn it on. Keep it on a trusted network, and do not forward its port to the internet.